CME600 is the world's first online O2/COx measurement analyzer,it is used for real-time accurate measurements of oxygen and flammable gases in the smoke.Two sensor are wrapped in the same probe,insert in the smoke directly.The double measurement of oxygen and flammable gases ensures a rapid and continuous gas data collection process, react quickly to the system of gas component changes and increased factory safety.
In COx, X is mean “equivalent to” .It's the sum of all the unburned molecules.Such as, CO, CH4, H2, etc.
These unburned molecules are the only components other than oxygen that can analyze the process of the combustion.High content of COx means an insufficient combustion process that is harmful to the atmosphere and is not conducive to control.
Feature: sampling free,maintenance-free,high temperature resistant,multicomponent
Depth of immersion of probe: ≤1850mm
O2/COx range: O2(0%/100%)
COx(0-2000ppm)
Measurement precision: ±0.2% O2 measurement value
Response time: 0.5s (air flow rate>10m/s)